emg2qwerty: A Large Dataset with Baselines for Touch Typing using Surface Electromyography
…40 Hz cutoff (removes DC drift, motion artifacts) 2. **Clock drift correction…
- Participants
- 108
- Size
- 223 GB
- Version
- vv2.0.0
- Updated
- Jul 10, 2026
100 results for "EMG artifact" · page 1 of 10 · ranked by relevance
…40 Hz cutoff (removes DC drift, motion artifacts) 2. **Clock drift correction…
A BIDS-formatted high-density surface EMG (HDsEMG) dataset from 16 young volunteers performing submaximal (10-80% MVC) isometric ankle dorsiflexions (tibialis anterior, n=8) or knee extensions (vastus lateralis, n=8). Signals were recorded with four 64-electrode arrays (256 channels in total) together with force signals, supporting the decomposition of extensive motor unit samples and the study of rate coding. It is a BIDS conversion of the data from Avrillon et al. 2024, produced with the MUniverse software.
A BIDS-formatted dataset of high-density surface EMG (HDsEMG) recordings from the right tibialis anterior of six healthy male participants. Four 64-channel grids (256 electrodes) recorded trapezoidal isometric dorsiflexion contractions at 30% and 50% of maximal voluntary contraction, together with force signals. The dataset supports studies of electrode grid design and motor unit identification.
A BIDS-formatted release of the Hyser high-density surface electromyogram (HD-sEMG) dataset. It contains 256-channel forearm EMG with simultaneous five-finger force recordings from 20 right-handed participants across two sessions. Tasks include 34 hand gestures, maximum voluntary contraction, and single-finger, multi-finger and random force-tracking tasks, supporting gesture recognition and force decoding research.
High-density surface EMG (HDsEMG) recordings from the right tibialis anterior of a single healthy participant performing submaximal isometric ankle dorsiflexions at 10 to 70 percent of maximal voluntary contraction. Signals were acquired with two 64-electrode arrays (128 electrodes total) alongside force measurements. The dataset includes labeled motor unit spike trains derived from concurrent invasive EMG, and supports motor unit decomposition research.
This dataset is a NEMAR re-host and EMG-BIDS conversion of the public emg2pose release from Meta Reality Labs. It contains 2 kHz, 16-channel wrist surface electromyography recordings paired with hand pose labels (joint angles) captured by a 26-camera motion-capture system. The release spans 193 users, 370 hours, and 29 behavioral stages, supporting benchmarking of sEMG-based hand pose estimation.
NEMAR Dataset nm000106: handwriting - Handwriting movement detection from EMG
NEMAR Dataset nm000105: discrete_gestures - Discrete hand gesture detection from EMG
NEMAR Dataset nm000107: wrist - Wrist movement control from EMG
[![DOI](https://img.shields.io/badge/DOI-10.82901%2Fnemar.on006386-blue…